Siemens flame detector datasheet 7404

Siemens flame detector datasheet 7404

Infrared flame detectors collective/SynoLINE300/600, AnalogPLUS/SynoLOOP, interactive lDF1191 flame detector for simple inside applications, detection with one infrared sensor lDF1192 flame detector for the most demanding application (inside and out-side), detection with 3 infrared sensors 5. On multiburner installations, each detector must respond only to the flame of the burner it is supervising. 6. Do not connect more than two C7061 Flame Detectors in parallel. Proper flame detector installation is the basis of a safe and reliable flame safeguard installation. Refer also to the burner manufacturer instructions. Find supplier datasheets for Flame Detectors on GlobalSpec. Flame detectors monitor and analyze incoming radiation at selected wavelengths.

MSA's FlameGard ® 5 MSIR Detector is an advanced multi-spectrum flame detector designed to provide superior false alarm immunity with the widest field of view. The detector employs a state-of-the-art multi-spectrum infrared (MSIR) sensor array with a sophisticated Neural Network Technology (NNT ... Combustion & Control Systems - offering Uv Cell Siemens Flame Detector QRA53.C27, Ac 220 - 240 V, Model Name/Number: Qra 53 C27 at Rs 20000.00/units in Mumbai, Maharashtra.

Siemens Industry Catalog - Building Technologies - HVAC Products - OEM products - Special sortiment - HCS - Sensors - QRI2A2.B180B - Infrared flame detector, front, cable 180cm, stripped+ferrules

Siemens make photoresistive flame detector is supplied with a metal protective tube having an external diameter of 17 mm. This type of detector is always secured with a flange and a clamp. Ultraviolet Flame Detector QRA2(1), QRA2M(1), QRA2.9 for supervision of gas flames, yellow or blue oilflames and for ignition spark proving. Operation: When the UV radiation of the flame in the position of the detector is high enough, the detector is activated during each half wave, giving a signal current. C7915A Infrared Flame Detector APPLICATION The C7915A Flame Detector includes a lead sulfide photocell that is sensitive to the infrared radiation emitted by the combustion of fuels such as natural gas, oil, and coal. • Particularly suitable for combination or dual-fuel applications. • When installed properly, can supervise the pilot flame and/

Siemens Building Technologies SpA CE1N7601e 05-04-2004 1/8 s 7 601 INTELLIGAS® Gas leak detection sy stem for heating rooms and similar environments LYC11 Electronic control unit for gas leak detection with single sensor aimed to drive a possible distance to the detector and to other cables Electrical connection of the flame detector It is important to achieve practically disturbance- and loss-free signal transmission: • Never run the detector cable together with other cables – Line capacitance reduces the magnitude of the flame signal – Use a separate cable

Datasheet 2D-3 (issue 7.0) Switchguard Circuit Controller Style U5A Author: Siemens Ltd Subject: Switchguard Circuit Controller Style U5A Keywords: datasheet 2D-3 Switchguard Circuit Controller Style U5A - Dual-Switch Detector for Points, Facing Point Lock and Other Sliding Equipment Created Date: 5/9/2000 7:14:31 PM Datasheet search engine for Electronic Components and Semiconductors, integrated circuits, diodes and other semiconductors. MSA's FlameGard ® 5 MSIR Detector is an advanced multi-spectrum flame detector designed to provide superior false alarm immunity with the widest field of view. The detector employs a state-of-the-art multi-spectrum infrared (MSIR) sensor array with a sophisticated Neural Network Technology (NNT ...

Flame detector without soft plastic plug. This type of detector is fitted with the help of a flange. A guide groove in the securing flange and a cam on the detector clamp ensure vibration-free mounting and make certain that the photo resistive flame detector is always correctly sited towards the flame. Flame detector with soft plastic plug. Siemens Landis QRA2 flame detector Photocell. These flame detectors have LOW sensitivity to be used for the supervision of gas flames, yellow or blue burning oil flames and for ignition spark proving. Installation Instructions Models AD2-P, AD2-PR and AD2-XHR INTRODUCTION Models AD2-P , AD2-PR and AD2-XHR (AD2 Series) from Siemens Building Technologies, Inc., are air duct monitoring housings containing sampling tubes. When used with a compatible smoke detector, smoke and combustion prod-ucts are detected for shutdown of the duct system and/or Ultraviolet Flame Detector QRA2(1), QRA2M(1), QRA2.9 for supervision of gas flames, yellow or blue oilflames and for ignition spark proving. Operation: When the UV radiation of the flame in the position of the detector is high enough, the detector is activated during each half wave, giving a signal current.

The infrared flame detector shall be a Cerberus Pyrotronics model S-2406. The infrared flame detector, model S-2406 shall have a four stage sensitivity selection. The infrared flame detector shall have dual sensors for the purpose of discriminating between infrared energy in the characteristic carbon dioxide spectral range (4.1 to 4.7 m M) and ... Siemens LFE10 - Flame Detector Relay 220V - The LFE10 is suited for the supervision of gas flames and luminous or blue-burning oil flames in connection with UV detectors QRA... or a flame rectification probe.

5. On multiburner installations, each detector must respond only to the flame of the burner it is supervising. 6. Do not connect more than two C7061 Flame Detectors in parallel. Proper flame detector installation is the basis of a safe and reliable flame safeguard installation. Refer also to the burner manufacturer instructions.

Datasheet 2D-3 (issue 7.0) Switchguard Circuit Controller Style U5A Author: Siemens Ltd Subject: Switchguard Circuit Controller Style U5A Keywords: datasheet 2D-3 Switchguard Circuit Controller Style U5A - Dual-Switch Detector for Points, Facing Point Lock and Other Sliding Equipment Created Date: 5/9/2000 7:14:31 PM

Flame Detector QRA4.U Flame detector for use with burner controls from Siemens Building Technologies for the supervision of gas or oil flames. The QRA4.U and this Data Sheet are intended for use by OEMs which integrate the flame detectors in their products. Use The flame detector is used for the supervision of gas flames, yellow- or blue ... Datasheet search engine for Electronic Components and Semiconductors, integrated circuits, diodes and other semiconductors.

MSA's FlameGard ® 5 MSIR Detector is an advanced multi-spectrum flame detector designed to provide superior false alarm immunity with the widest field of view. The detector employs a state-of-the-art multi-spectrum infrared (MSIR) sensor array with a sophisticated Neural Network Technology (NNT ... detector locking kit, which contains 50 detector locks and an installation tool to prevent unauthorized removal of the detector head. Model DB-11 has decorative plugs to cover the outer-mounting screw holes. Model OP921may be installed on the same initiating circuit with the Siemens Model ‘H’-series detectors [when used with The infrared flame detector shall be a Cerberus Pyrotronics model S-2406. The infrared flame detector, model S-2406 shall have a four stage sensitivity selection. The infrared flame detector shall have dual sensors for the purpose of discriminating between infrared energy in the characteristic carbon dioxide spectral range (4.1 to 4.7 m M) and ...