Slug test data sheet

Slug test data sheet

Test Performance and Data Collection Data collection should include establishment of water level trends prior to and following the application of the slug. Pre-test measurements should be made until any changes have stabilized and should be taken for a period of time, at least as long as the expected recovery period. Analysis and Evaluation of Pumping Test Data. International Institute for Land Development and Improvement. McLane, Gerald A., Deborah A. Harrity, and Kurt O. Thomsen. 1990?. Slug testing in highly permeable aquifer using a pneumatic method. Superfund '90, pp 300-303. Pandit, Nintin S., and Robert F. Miner. 1986. Interpretation of slug test data.

Material Safety Data Sheet MSDS Number: 000000002175 Bayer Advanced Dual Action Snail & Slug Killer Bait Ready-To-Use MSDS Version 1.0 Page 4 of 5 SECTION 13. DISPOSAL CONSIDERATIONS General Disposal Guidance Do not contaminate water, food, or feed by disposal. Do not re-use empty containers. Never place unused product down any indoor or ... www.hydrology.nl

Multi-Well Slug Tests. AQTESOLV includes slug test data analysis methods such as the KGS Model (Hyder et al. 1994) that may be used to analyze multi-well slug tests (interference tests) in confined or unconfined aquifers. Analysis of multi-well slug test in a confined aquifer using KGS Model (Hyder et al. 1994). Technology Sheet AquiferTest Pro Pumping Test and Slug Test Data Analysis Software Estimating the hydraulic properties of aquifers and aquitards (hydraulic conductivity, storativity, transmissivity) Predicting drawdown effects resulting from groundwater pumping Optimizing pumping test design considering well diameter, pumping rate, screened ... May 27, 2016 · Slug tests have the advantage of being quick, inexpensive to perform, and do not generate water that requires disposal, which is an important consideration at contaminated sites. The quality of data obtained from slug tests is strongly dependent on well and borehole conditions, particularly skin effects. Test data are not available for the complete mixture. Classification procedure The method for classification of the mixture is based on ingredients of the mixture (additivity formula). Classification acc. to OSHA "Hazard Communication Standard" (29 CFR 1910.1200) This mixture does not meet the criteria for classification. Acute toxicity

does not guarantee its accuracy or completeness. Health and safety precautions in this data sheet may not be adequate for all individuals and/or situations. It is the user’s obligation to evaluate and use this product safely and to comply with all applicable laws and regulations; in so doing, user assumes all risk in use of the material.

Test Performance and Data Collection Data collection should include establishment of water level trends prior to and following the application of the slug. Pre-test measurements should be made until any changes have stabilized and should be taken for a period of time, at least as long as the expected recovery period. Superposition of normalized data and best-fit type curve for test 3. Conclusions Two new procedures have been presented for the analysis of response data from slug tests performed in formations of high hydraulic conductivity. Both approaches can be performed quite rapidly with commonly available spreadsheet and scientific-graphics software. SAFETY DATA SHEET Issuing Date 5/01/2015 The supplier identified below generated this SDS using the UL SDS template. UL did not test, certify, or approve the substance described in this SDS, and all information in this SDS was provided by the supplier or was reproduced from publically available regulatory data sources. UL makes no representations

Jan 30, 2014 · As soon as I was able, I ordered a box of their new Thug Slugs and began the process of giving the product a preliminary range test. Thug Slug overview. The Thug Slug is the most recent addition to BPI’s line of slug components for handloading. recovery test data from the sho'rt-term aquifer test provides an estimate of aquifer transmissivity, while the slug test analyses provide hydraulic conductivity estimates. Table 2. Analysis Results from the Alluvial Aquifer Short-Term Aquifer Test and Slug Tests Aquifer Test Analysis Slug Test Analysis With the slug test the hydraulic conductivity or trans-missibility of an aquifer is determined from the rate of rise of the water level in a well after a certain volume or 'slug' of water is suddenly removed from the welL. The slug test is simpler and quicker than the Theis pumping test because observation wells and pumping the well are not ...

Name Eraza Zero Slug Killer MAPP 18411 PCS 06005 1.2 Relevant Identified Uses of the Mixture Usage Slug Killer 1.3 Details of the Supplier of the Safety Data Sheet Supplier Westland Horticulture Ltd 14 Granville Industrial Estate Granville Road Dungannon County Tyrone BT70 1NJ Email [email protected] AquiferTest Pro 4.0 provides graphical analysis and reporting of pumping test and slug data for Confined Aquifers, Unconfined Aquifers, Leaky Aquifers, and Fractured Rock Aquifers Scientific Software Group is the premier provider of groundwater software, environmental software, groundwater modeling software, surface water modeling software, hydrology software, hydraulic engineering software ...

Several spreadsheets have been developed for the analysis of aquifer-test and slug-test data. Each spreadsheet incorporates analytical solution(s) of the partial differential equation for ground-water flow to a well for a specific type of condition or aquifer. Slug Test Analysis Software : New V2.0. New V2.0 Slug Test Analysis Software is now available from Geoprobe Systems®. The Slug Test Analysis Software is a graphical interface used to model the data collected from a slug test conducted in direct push tools or conventional monitoring wells that provide either an over damped or underdamped response.

Technology Sheet AquiferTest Pro Pumping Test and Slug Test Data Analysis Software Estimating the hydraulic properties of aquifers and aquitards (hydraulic conductivity, storativity, transmissivity) Predicting drawdown effects resulting from groundwater pumping Optimizing pumping test design considering well diameter, pumping rate, screened ... Safety Data Sheet of 4 Infosafe No ™ 3NV0G Issue Date : July 2017 ISSUED by NUFARM Product Name :Slugout All Weather Slug and Snail Bait Not classified as hazardous Acute Toxicity - LC50 (rat) (4hr) >15 mg/l Inhalation Symptoms of mild poisoning include nausea, salivation, vomiting, diarrhoea, abdominal pain and muscle spasms.

Material Safety Data Sheet May be used to comply with OSHA’s Hazard Communication Standard, 49 CFR 1910.1200. Standard must be consulted for specific requirements U.S. Department of Labor Occupational Safety and Health Administration MSDS-DD001 Rev. 4, Dated 7-25-08 Page 2 of 5 Extinguishing Media N/A – Ordnance devices are not extinguishable.

4.2 Field Procedures For Slug Testing 4.2.1 Slug Injection Test Field Procedures An excess head, large enough to provide meaningful data for slug test analysis, will be created in each piezometer or well tested during the slug injection test. Select a slug size that will provide a maximum amount of transducer, all data will be stored internally or on computer diskettes or tape. The information will be transferred directly to the main computer and analyzed. A computer printout of the data shall be maintained in the files as documentation. If the slug test data is collected and recorded manually, the slug test data form (Figure 1, Appendix ...

Analysis and Evaluation of Pumping Test Data. International Institute for Land Development and Improvement. McLane, Gerald A., Deborah A. Harrity, and Kurt O. Thomsen. 1990?. Slug testing in highly permeable aquifer using a pneumatic method. Superfund '90, pp 300-303. Pandit, Nintin S., and Robert F. Miner. 1986. Interpretation of slug test data. Spreadsheets for the Analysis of Aquifer-Test and Slug-Test Data, Version 1.2. By Keith J. Halford and Eve L. Kuniansky. Preface. This report documents several spreadsheets that have been developed for the analysis of aquifer-pumping test and slug-test data. Estimates hydraulic conductivity from slug-test data using the van der Kamp (1976) method. This method was developed for the analysis of slug-test data from highly transmissive aquifers, as evidenced by oscillatory water-level response to a slug displacement. SAFETY DATA SHEET Issuing Date 5/01/2015 The supplier identified below generated this SDS using the UL SDS template. UL did not test, certify, or approve the substance described in this SDS, and all information in this SDS was provided by the supplier or was reproduced from publically available regulatory data sources. UL makes no representations transducer, all data will be stored internally or on computer diskettes or tape. The information will be transferred directly to the main computer and analyzed. A computer printout of the data shall be maintained in the files as documentation. If the slug test data is collected and recorded manually, the slug test data form (Figure 1, Appendix ...